RT Conference Proceedings T1 Digital control of a three-phase four-leg inverter under unbalanced voltage conditions A1 Vechiu, I. A1 Curea, O. A1 Camblong, H. A1 Ceballos, S. A1 Villate, J. L. AB In this paper, the implementation of an innovative inverter control strategy based on the symmetrical components is presented. Symmetrical components of the inverter output voltage and current are decomposed into dq DC quantities to control a three-phase four-leg inverter. This kind of inverter can be a good choice for the applications with hybrid power system based on renewable energy used to supply unbalanced loads. The addition of a fourth leg provides an extra degree of freedom, making possible to handle the neutral current caused by the unbalanced load. Simulation results are compared with experimental results for a prototype inverter to verify the validity of the proposed control strategy. SN 9075815115 SN 9789075815115 YR 2007 FD 2007 LK https://hdl.handle.net/11556/2785 UL https://hdl.handle.net/11556/2785 LA eng NO Vechiu , I , Curea , O , Camblong , H , Ceballos , S & Villate , J L 2007 , Digital control of a three-phase four-leg inverter under unbalanced voltage conditions . in 2007 European Conference on Power Electronics and Applications, EPE . , 4417447 , 2007 European Conference on Power Electronics and Applications, EPE , 2007 European Conference on Power Electronics and Applications, EPE , Aalborg , Denmark , 2/09/07 . https://doi.org/10.1109/EPE.2007.4417447 NO conference DS TECNALIA Publications RD 28 jul 2024