Assessment on the Efficiency of an Active Solar Thermal Facade: Study of the Effect of Dynamic Parameters and Experimental Analysis When Coupled/Uncoupled to a Heat Pump: Study of the effect of dynamic parameters and experimental analysis when coupled/uncoupled to a heat pump

dc.contributor.authorElguezabal, Peru
dc.contributor.authorLopez, Alex
dc.contributor.authorBlanco, Jesus Maria
dc.contributor.authorChica, Jose Antonio
dc.contributor.institutionECOEFICIENCIA DE PRODUCTOS DE CONSTRUCCIĂ“N
dc.contributor.institutionSG
dc.date.issued2020
dc.descriptionPublisher Copyright: © 2020 by the authors
dc.description.abstractThe building sector presents poor performance in terms of energy efficiency and is looking for effective alternatives aimed at reducing the use of fossil fuels. The facade is a key element able to harness renewable energy as an Active Solar Thermal Facade (ASTF). The main purpose of this study is the assessment of a novel design concept based on a steel sandwich panel technology. The performance of the active system will be first addressed by a parametric study in order to analyze its behavior and secondly, by describing a real case based on an experimental test by connecting the active panels to a heat pump. The study shows the impact of solar irradiation and mass flow on the thermal jump achieved, while ambient and fluid inlet temperatures are the most influencing parameters in the efficiency of the facade. When coupled to the heat pump, results from a measurement campaign demonstrate a remarkable improvement in the performance of the ASTF. The results presented provide significant proof about the benefits of a synergetic combination of both technologies—solar facades and heat pumps—as efficient alternatives for the building sector, aiming to improve energy efficiency as well as reduce their dependence on non-renewable sources.en
dc.description.statusPeer reviewed
dc.format.extent1
dc.format.extent5774563
dc.identifier.citationElguezabal , P , Lopez , A , Blanco , J M & Chica , J A 2020 , ' Assessment on the Efficiency of an Active Solar Thermal Facade: Study of the Effect of Dynamic Parameters and Experimental Analysis When Coupled/Uncoupled to a Heat Pump : Study of the effect of dynamic parameters and experimental analysis when coupled/uncoupled to a heat pump ' , Energies , vol. 13 , no. 3 , 597 , pp. 597 . https://doi.org/10.3390/en13030597
dc.identifier.doi10.3390/en13030597
dc.identifier.issn1996-1073
dc.identifier.otherresearchoutputwizard: 11556/875
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85078977563&partnerID=8YFLogxK
dc.language.isoeng
dc.relation.ispartofEnergies
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.keywordsActive solar thermal facade
dc.subject.keywordsSandwich panels
dc.subject.keywordsThermal efficiency
dc.subject.keywordsUnglazed collector
dc.subject.keywordsSolar assisted heat pumps
dc.subject.keywordsActive solar thermal facade
dc.subject.keywordsSandwich panels
dc.subject.keywordsThermal efficiency
dc.subject.keywordsUnglazed collector
dc.subject.keywordsSolar assisted heat pumps
dc.subject.keywordsRenewable Energy, Sustainability and the Environment
dc.subject.keywordsBuilding and Construction
dc.subject.keywordsFuel Technology
dc.subject.keywordsEngineering (miscellaneous)
dc.subject.keywordsEnergy Engineering and Power Technology
dc.subject.keywordsEnergy (miscellaneous)
dc.subject.keywordsControl and Optimization
dc.subject.keywordsElectrical and Electronic Engineering
dc.subject.keywordsSDG 7 - Affordable and Clean Energy
dc.subject.keywordsFunding Info
dc.subject.keywordsThis research was partially funded by the Basque Government through IT781-13 and IT1314-19 research_x000D_ groups and by the University of the Basque Country UPV/EHU through PES17/25. Additionally, TECNALIA_x000D_ Research & Innovation supported the research activities research through a cooperation agreement (PT10516) with_x000D_ UPV/EHU.
dc.subject.keywordsThis research was partially funded by the Basque Government through IT781-13 and IT1314-19 research_x000D_ groups and by the University of the Basque Country UPV/EHU through PES17/25. Additionally, TECNALIA_x000D_ Research & Innovation supported the research activities research through a cooperation agreement (PT10516) with_x000D_ UPV/EHU.