Triple function substation and high-efficiency micro booster heat pump for Ultra Low Temperature District Heating

dc.contributor.authorLumbreras Mugaguren, Mikel
dc.contributor.authorGaray, Roberto
dc.contributor.authorSánchez Zabala, Víctor
dc.contributor.authorKorsholm Østergaard, Kasper
dc.contributor.authorCaramaschi, Matteo
dc.contributor.authorGaray Martínez, Roberto
dc.contributor.authorKorsholmstergaard, Kasper
dc.contributor.institutionTecnalia Research & Innovation
dc.contributor.institutionEDIFICACIÓN DE ENERGÍA POSITIVA
dc.date.issued2019-10-23
dc.descriptionPublisher Copyright: © 2019 Published under licence by IOP Publishing Ltd.
dc.description.abstractDistrict-Heating (DH) covers around the 9% of the total heat demand in the EU, with a proven highperformance levels and low operational costs. DH may suffer adaptations in order to maintain competitiveness with individual heating systems. The most important one is the reduction of supply temperatures up to 50°C, emerging the concept of Ultra Low Temperature (ULT) DH. ULT DH allows the transmission and distribution heat losses minimization, since heat losses are proportional to the temperature-gradient between supply line the ambient, increasing overall system performance. Furthermore, enables the integration of low-grade energy sources with low marginal costs, such as solar thermal energy or waste heat from industrial and commercial buildings. This study presents the combination of a novel 3 function-scheme (3FS) substation and a micro booster heat pump for domestic hot water. The novel design of the substation allows different operation modes between the grid and the building according to the temperature level and demand range every moment. Regarding the microbooster, this unit is used directly to lift the temperature of the domestic hot water (DHW), so that risk of legionella is avoided and that the required comfort temperature is reached. Preliminary test for the energy performance of the booster heat pump was measured on serially produced units according to tapping profiles and methodologies of standard EN16147. DHW coefficients of performance of 5.2 and 8.5 were measured for heat source supply temperatures respectively of 25 and 40 °C and return temperatures of 22 and 30 °C. This paper explores the possible operational modes of a 3FS in combination with a Building Integrated Solar Thermal System (BISTS) and a Microbooster heat pump.en
dc.description.statusPeer reviewed
dc.format.extent1
dc.format.extent599900
dc.identifier.citationLumbreras Mugaguren , M , Garay , R , Sánchez Zabala , V , Korsholm Østergaard , K , Caramaschi , M , Garay Martínez , R & Korsholmstergaard , K 2019 , ' Triple function substation and high-efficiency micro booster heat pump for Ultra Low Temperature District Heating ' , IOP Conference Series: Materials Science and Engineering , vol. 609 , no. 5 , 052008 , pp. 52008 . https://doi.org/10.1088/1757-899x/609/5/052008
dc.identifier.doi10.1088/1757-899x/609/5/052008
dc.identifier.issn1757-8981
dc.identifier.otherresearchoutputwizard: 11556/812
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=85074534604&partnerID=8YFLogxK
dc.language.isoeng
dc.relation.ispartofIOP Conference Series: Materials Science and Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.keywordsCoefficients of performance
dc.subject.keywordsComfort temperatures
dc.subject.keywordsLosses minimizations
dc.subject.keywordsSolar thermal energy
dc.subject.keywordsHeat losses
dc.subject.keywordsDistrict heating
dc.subject.keywordsIndoor air pollution
dc.subject.keywordsCoefficients of performance
dc.subject.keywordsComfort temperatures
dc.subject.keywordsLosses minimizations
dc.subject.keywordsSolar thermal energy
dc.subject.keywordsHeat losses
dc.subject.keywordsDistrict heating
dc.subject.keywordsIndoor air pollution
dc.subject.keywordsGeneral Materials Science
dc.subject.keywordsGeneral Engineering
dc.subject.keywordsSDG 7 - Affordable and Clean Energy
dc.titleTriple function substation and high-efficiency micro booster heat pump for Ultra Low Temperature District Heatingen
dc.typeconference output