This paper is related to faults that can appear in multilevel (ML) inverters, which have a high number of components. This is a subject of increasing importance in high-power inverters. First, methods to identify a fault are classified and briefly described for each topology. In addition, a number of strategies and hardware modifications that allow for operation in faulty conditions are also presented. As a result of the analyzed works, it can be concluded that ML inverters can significantly increase their availability and are able to operate even with some faulty components.
Description
Citation
Lezana , P , Pou , J , Meynard , T A , Rodriguez , J , Ceballos , S & Richardeau , F 2010 , ' Survey on fault operation on multilevel inverters ' , IEEE Transactions on Industrial Electronics , vol. 57 , no. 7 , 5256213 , pp. 2207-2218 . https://doi.org/10.1109/TIE.2009.2032194