Fault-tolerant neutral-point-clamped converter solutions based on including a fourth resonant leg

dc.contributor.authorCeballos, Salvador
dc.contributor.authorPou, Josep
dc.contributor.authorZaragoza, Jordi
dc.contributor.authorRobles, Eider
dc.contributor.authorVillate, José Luis
dc.contributor.authorMartín, José Luis
dc.contributor.institutionPOWER ELECTRONICS AND SYSTEM EQUIPMENT
dc.contributor.institutionRENOVABLES OFFSHORE
dc.contributor.institutionGENERAL
dc.date.accessioned2024-07-24T12:10:28Z
dc.date.available2024-07-24T12:10:28Z
dc.date.issued2011-06
dc.description.abstractThis paper presents a new three-level topology based on the neutral-point (NP)-clamped converter. An additional leg is added to the basic topology. The main purpose of this leg is to provide the converter with fault-tolerant capabilities. In addition, during normal operation mode, the fourth leg can be used to balance the NP voltage. In this way, the low-frequency voltage oscillations that appear in the NP under some operating conditions are cancelled out effectively. As a result, the modulation strategy of the three main legs of the converter does not have to take care of the voltage balance and can focus on other aspects such as, for instance, minimizing the switching losses of the converter. However, the inclusion of the fourth leg produces some additional losses. A resonant topology is proposed to minimize the switching losses of this leg. Three different fault-tolerant solutions based on the fourth-leg topology are presented. A comparison of these topologies showing their respective advantages and drawbacks is made. Experimental results are presented to show the viability of this approach.en
dc.description.sponsorshipManuscript received January 11, 2010; revised May 7, 2010; accepted June 28, 2010. Date of publication August 23, 2010; date of current version May 13, 2011. This work was supported in part by the Ministerio de Industria and the Ministerio de Ciencia y Tecnología of Spain under Projects CONFIA (G48870406/06), ENE2004-07881-C03-00, and ENE2007-67033-C03-00, by the Basque Country Government under SAIOTEK and EMAITEK Program, by the Torres Quevedo Program, and by the Department d’Universitats Re-cerca i Societat de la Informació of the Generalitat de Catalunya, under Grants 2004BE00105 and 2005BE00481.
dc.description.statusPeer reviewed
dc.format.extent11
dc.identifier.citationCeballos , S , Pou , J , Zaragoza , J , Robles , E , Villate , J L & Martín , J L 2011 , ' Fault-tolerant neutral-point-clamped converter solutions based on including a fourth resonant leg ' , IEEE Transactions on Industrial Electronics , vol. 58 , no. 6 , 5556001 , pp. 2293-2303 . https://doi.org/10.1109/TIE.2010.2069075
dc.identifier.doi10.1109/TIE.2010.2069075
dc.identifier.issn0278-0046
dc.identifier.urihttps://hdl.handle.net/11556/4080
dc.identifier.urlhttp://www.scopus.com/inward/record.url?scp=79956290764&partnerID=8YFLogxK
dc.language.isoeng
dc.relation.ispartofIEEE Transactions on Industrial Electronics
dc.relation.projectIDBasque Country Government
dc.relation.projectIDGeneralitat de Catalunya, 2004BE00105-2005BE00481
dc.relation.projectIDMinisterio de Ciencia y Tecnología, MICYT, ENE2004-07881-C03-00-G48870406/06-ENE2007-67033-C03-00
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subject.keywordsEfficiency
dc.subject.keywordsfault tolerance
dc.subject.keywordsmultilevel converter
dc.subject.keywordsneutral-point (NP)-clamped (NPC) converter
dc.subject.keywordsreliability
dc.subject.keywordsresonant converters
dc.subject.keywordsvoltage oscillation
dc.subject.keywordsControl and Systems Engineering
dc.subject.keywordsElectrical and Electronic Engineering
dc.titleFault-tolerant neutral-point-clamped converter solutions based on including a fourth resonant legen
dc.typejournal article