Browsing by Keyword "tactile communication"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Electrotactile Communication via Matrix Electrode Placed on the Torso Using Fast Calibration, and Static vs. Dynamic Encoding(2022-10) Malešević, Jovana; Kostić, Miloš; Jure, Fabricio A.; Spaich, Erika G.; Došen, Strahinja; Ilić, Vojin; Bijelić, Goran; Štrbac, Matija; SGElectrotactile stimulation is a technology that reproducibly elicits tactile sensations and can be used as an alternative channel to communicate information to the user. The presented work is a part of an effort to develop this technology into an unobtrusive communication tool for first responders. In this study, the aim was to compare the success rate (SR) between discriminating stimulation at six spatial locations (static encoding) and recognizing six spatio-temporal patterns where pads are activated sequentially in a predetermined order (dynamic encoding). Additionally, a procedure for a fast amplitude calibration, that includes a semi-automated initialization and an optional manual adjustment, was employed and evaluated. Twenty subjects, including twelve first responders, participated in the study. The electrode comprising the 3 × 2 matrix of pads was placed on the lateral torso. The results showed that high SRs could be achieved for both types of message encoding after a short learning phase; however, the dynamic approach led to a statistically significant improvement in messages recognition (SR of 93.3%), compared to static stimulation (SR of 83.3%). The proposed calibration procedure was also effective since in 83.8% of the cases the subjects did not need to adjust the stimulation amplitude manually.Item Encoding of spatial patterns using electrotactile stimulation via a multi-pad electrode placed on the torso(2022-10) Jure, Fabricio A.; Spaich, Erika G.; Malešević, Jovana; Kostić, Miloš; Štrbac, Matija; Došen, Strahinja; SGBackground: Tactile stimulation can be used to convey information to a user in different scenarios while avoiding overloading other senses. Tactile messages can be transmitted as spatial patterns, potentially allowing for a high information throughput. The aim of the present study was to design and test different encoding schemes to determine the best approach for conveying spatial patterns. Methods: Encoding schemes with simultaneous (SIM) and sequential pad activation (SEQ) were evaluated, including four SEQ variants designed to potentially facilitate the recognition. In SEQ-col and SEQ-row, the column and row of the activated pad were signified using different frequencies, while SEQ-all and SEQ-all-fast included the activation of all pads where those belonging to the pattern were indicated by changes in frequency (ON pads). The success rate (SR) of the pattern identification and the response time were quantified in 15 participants who recognized 20 patterns delivered through a 3 × 2 pad matrix placed on the lateral torso. Results: SIM was not a feasible method to present the patterns (median, 15%; IQR, 5%). The SR improved with SEQ (median, 60%; IQR, 20%) and further increased with additional cues, particularly with SEQ-row (median, 78.3%; IQR, 23.3%) and SEQ-all (median, 96.7%; IQR, 5%). Importantly, the stimulation time of SEQ-all could be decreased without a substantial drop in accuracy (SEQ-all-fast: median, 89.2%; IQR, 19.2%). Conclusions: The spatiotemporal stimulation with sequential activation of all pads (SEQ-all) seems to be the method of choice when conveying tactile messages as spatial patterns. This is an important outcome for increasing the information bandwidth of communication through the tactile channel.