Browsing by Author "Garay Martínez, Roberto"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item RELaTED, decentralized & renewable Ultra Low Temperature District Heating, concept conversion from traditional district heating(2019-10-23) Lumbreras Mugaguren, Mikel; Garay, Roberto; Sánchez Zabala, Víctor; Garay Martínez, Roberto; Tecnalia Research & Innovation; EDIFICACIÓN DE ENERGÍA POSITIVADistrict Heating (DH) are a very efficient system for heating in urban areas and they are considered as key elements for the de-carbonization of the European Cities. High performance levels and low operational energy costs are part of the identity of these heating networks. The reduction of supply-line temperatures allows the possibility to introduce new low-grade and renewable source energy production, reducing dependence on fossil fuel-based energy plants. Moreover, heat-losses in distribution pipelines are also reduced, since the gradient temperature between supply line and ambient temperature is reduced. Operation of decentralized & Ultra Low Temperature (ULT) systems may adapt for the introduction of weather-dependent, distributed heat sources such as solar systems. Furthermore, although very dependent on local availability, waste heat streams from commercial and industrial installations are also considered because of the stability of heat supply all year round, resulting in minimally carbon intensive processes. Regarding building features, the reduced heat load derived from the transition from current buildings to Nearly Zero Energy Buildings (NZEB), RELaTED allows for the novel concept called prosumer, where buildings can deliver energy to the grid from decentralized energy sources installed in the building. In RELaTED, different subsystems are being developed by different industrial partners, to prove their efficiency in 4 real demonstration sites: Tartu (Estonia), Belgrade (Serbia), Vinge (Denmark) and Iurreta (Spain). A 3-FS (3-Function Scheme) DH substation that permits buildings to become prosumers. Two types of solar collectors, one is an all polymeric glazed collector and the second one is an unglazed collector, both as components of Building Integrated Large Solar Thermal Systems (BILSTS) solar loop. Finally, a reversible and high efficiency heat pump for domestic hot water is being developed. In this paper, an approach to ULT concept is studied, including transitory phases of the conversion.Item Triple function substation and high-efficiency micro booster heat pump for Ultra Low Temperature District Heating(2019-10-23) Lumbreras Mugaguren, Mikel; Garay, Roberto; Sánchez Zabala, Víctor; Korsholm Østergaard, Kasper; Caramaschi, Matteo; Garay Martínez, Roberto; Korsholmstergaard, Kasper; Tecnalia Research & Innovation; EDIFICACIÓN DE ENERGÍA POSITIVADistrict-Heating (DH) covers around the 9% of the total heat demand in the EU, with a proven highperformance levels and low operational costs. DH may suffer adaptations in order to maintain competitiveness with individual heating systems. The most important one is the reduction of supply temperatures up to 50°C, emerging the concept of Ultra Low Temperature (ULT) DH. ULT DH allows the transmission and distribution heat losses minimization, since heat losses are proportional to the temperature-gradient between supply line the ambient, increasing overall system performance. Furthermore, enables the integration of low-grade energy sources with low marginal costs, such as solar thermal energy or waste heat from industrial and commercial buildings. This study presents the combination of a novel 3 function-scheme (3FS) substation and a micro booster heat pump for domestic hot water. The novel design of the substation allows different operation modes between the grid and the building according to the temperature level and demand range every moment. Regarding the microbooster, this unit is used directly to lift the temperature of the domestic hot water (DHW), so that risk of legionella is avoided and that the required comfort temperature is reached. Preliminary test for the energy performance of the booster heat pump was measured on serially produced units according to tapping profiles and methodologies of standard EN16147. DHW coefficients of performance of 5.2 and 8.5 were measured for heat source supply temperatures respectively of 25 and 40 °C and return temperatures of 22 and 30 °C. This paper explores the possible operational modes of a 3FS in combination with a Building Integrated Solar Thermal System (BISTS) and a Microbooster heat pump.