dc.identifier.citationM. Lieblich, S. Barriuso, J. Ibáñez, L. Ruiz-de-Lara, M. Díaz, J.L. Ocaña, A. Alberdi, J.L. González-Carrasco, On the fatigue behavior of medical Ti6Al4V roughened by grit blasting and abrasiveless waterjet peening, Journal of the Mechanical Behavior of Biomedical Materials, Volume 63, October 2016, Pages 390-398, ISSN 1751-6161, http://dx.doi.org/10.1016/j.jmbbm.2016.07.011.en
dc.identifier.issn1751-6161en
dc.identifier.urihttp://hdl.handle.net/11556/346
dc.description.abstractFlat fatigue specimens of biomedical Ti6Al4V ELI alloy were surface-processed by high pressure waterjet peening (WJP) without abrasive particles using moderate to severe conditions that yield roughness values in the range of those obtained by commercial grit blasting (BL) with alumina particles. Fatigue behavior of WJP and BL specimens was characterized under cyclical uniaxial tension tests (R=0.1). The emphasis was put on a comparative analysis of the surface and subsurface induced effects and in their relevance on fatigue behavior. Within the experimental setup of this investigation it resulted that blasting with alumina particles was less harmful for fatigue resistance than abrasiveless WJP. BL specimens resulted in higher subsurface hardening and compressive residual stresses. Specimens treated with more severe WJP parameters presented much higher mass loss and lower compressive residual stresses. From the analysis performed in this work, it follows that, in addition to roughness, waviness emerges as another important topographic parameter to be taken into account to try to predict fatigue behavior. It is envisaged that optimization of WJP parameters with the aim of reducing waviness and mass loss should lead to an improvement of fatigue resistanceen
dc.description.sponsorshipThe authors acknowledge support from projects MINECO (MAT 2012-37736-C05-01 and MAT 2012-37782), HZB (BESSY, Proposal 14100041) and Comunidad de Madrid (Multimat Challenge S2013/MIT-2862). The CIBER of Bioingenieria, Biomateriales y Nanomedicina is supported by the ISCIII. Thanks are also due to Jesus Chao for his help with the tensile tests, Dr. Gaspar Gonzalez-Doncel for his help with measurement of residual stresses, both from CENIM, and Alfredo Suarez from Tecnalia for his help with the waterjet processing. Naiara Gallardo and Edurne Laurin are greatfully acknowledged for their technical assistance, as well as the laboratory of Microscopy (A. Garcia and A. Tomas).en
dc.language.isoengen
dc.publisherELSEVIER SCIENCE BV, PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDSen
dc.titleOn the fatigue behavior of medical Ti6Al4V roughened by grit blasting and abrasiveless waterjet peeningen
dc.typearticleen
dc.identifier.doi10.1016/j.jmbbm.2016.07.011en
dc.isiYesen
dc.rights.accessRightsembargoedAccessen
dc.subject.keywordsTi6Al4Ven
dc.subject.keywordsGrit blastingen
dc.subject.keywordsWaterjet peeningen
dc.subject.keywordsFatigue resistanceen
dc.subject.keywordsResidual stressesen
dc.subject.keywordsSurface topographyen
dc.identifier.essn1878-0180en
dc.journal.titleJournal of the Mechanical Behavior of Biomedical Materialsen
dc.page.final398en
dc.page.initial390en
dc.volume.number63en