Show simple item record

dc.contributor.authorBoubaris, Alexandros
dc.contributor.authorKyritsis, Anastasios
dc.contributor.authorBabouras, Konstantinos
dc.contributor.authorFrantzeskakis, Syllas
dc.contributor.authorPapanikolaou, Nick
dc.contributor.authorPapadopoulos, Theofilos
dc.contributor.authorVidaurrazaga, Iñigo
dc.contributor.authorAlonso, Ricardo
dc.date.accessioned2021-10-14T11:44:35Z
dc.date.available2021-10-14T11:44:35Z
dc.date.issued2021-03
dc.identifier.citationBoubaris, Alexandros, Anastasios Kyritsis, Konstantinos Babouras, Syllas Frantzeskakis, Nick Papanikolaou, Theofilos Papadopoulos, Iñigo Vidaurrazaga, and Ricardo Alonso. “Study on the Effectiveness of Commercial Anti‐islanding Algorithms in the Prospect of Mass Penetration of PVs in Low‐voltage Distribution Networks.” IET Energy Systems Integration 3, no. 1 (February 21, 2021): 39–59. doi:10.1049/esi2.12007.en
dc.identifier.issn2516-8401en
dc.identifier.urihttp://hdl.handle.net/11556/1213
dc.description.abstractIn the coming years, distribution grids will be progressively flooded by renewable energy sources (RES) that will be interconnected with the main grid through power electronic converters. Photovoltaics (PVs) are one of the most promising renewable technologies even for densely built-up areas where space problems are inevitable. The high penetration prospect of PV facilities on low-voltage distribution networks raises questions regarding the necessity of advanced functions that will enable electronically coupled RES to support the operation of distribution grids and to enhance their reliability. In this context, the objective of this study is to investigate the effectiveness of various islanding prevention measures installed in commercial PV inverters, when multiple inverters are operating in parallel with a low-voltage distribution network (LVDN). Extensive experiments were performed under various PV penetration levels, linear/non-linear load and over/under voltage and over/under frequency conditions, as well as for various values of total harmonic distortion of the mains voltage. Further to the primary statistical analysis, the results were analysed in depth by advanced mathematical methods such as box plot and cluster analysis. The findings of this study indicate that commercial anti-islanding techniques present a high probability of failure in the case of multiple PV units at the same point of common coupling, calling for new and more advanced algorithms.en
dc.description.sponsorshipEuropean Commission, H2020, 654113en
dc.language.isoengen
dc.publisherJohn Wiley and Sons Incen
dc.rightsAttribution 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.titleStudy on the effectiveness of commercial anti‐islanding algorithms in the prospect of mass penetration of PVs in low‐voltage distribution networksen
dc.typejournal articleen
dc.identifier.doi10.1049/esi2.12007en
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/654113/EU/European Research Infrastructure supporting Smart Grid Systems Technology Development, Validation and Roll Out/ERIGriden
dc.rights.accessRightsopen accessen
dc.subject.keywordsDistributed power generationen
dc.subject.keywordsElectric invertersen
dc.subject.keywordsRenewable energy resourcesen
dc.subject.keywordsCluster analysisen
dc.subject.keywordsIslanding preventionen
dc.issue.number1en
dc.journal.titleIET Energy Systems Integrationen
dc.page.final59en
dc.page.initial39en
dc.volume.number3en


Files in this item

Thumbnail

    Show simple item record

    Attribution 4.0 InternationalExcept where otherwise noted, this item's license is described as Attribution 4.0 International